{"title":"Battery Management Systems (BMS)","description":"","products":[{"product_id":"victron-lynx-smart-bms-1000-battery-management-system-f-lithium-smart-batteries","title":"Victron Lynx Smart BMS 1000 Battery Management System f\/Lithium Smart Batteries","description":"\u003cp\u003e\u003cstrong\u003eLynx Smart BMS 1000 Battery Management System for Lithium Smart Batteries\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe Lynx Smart BMS is a dedicated Battery Management System (BMS) for the Victron Lithium Battery Smart batteries. These batteries are Lithium Iron Phosphate (LiFePO4) batteries and are available in 12.8 V or 25.6 V in various capacities. They can be connected in series, parallel, and series\/parallel so that a battery bank can be built for system voltages of 12V, 24 V, or 48 V. The maximum number of batteries in one system is 20, which results in a maximum energy storage of 84 kWh in a 12 V and up to 102 kWh in a 24 V1) and 48 V1) system.\u003c\/p\u003e\u003cp\u003eOut of the various available BMSes, the Lynx Smart BMS is the most feature-rich and complete option and integrates seamlessly into the Lynx Distributor system. This model is a 1000 A (M10) version.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBuilt-in 1000 A Contactor\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe contactor acts as a secondary safety system to protect the battery in case the primary controls (ATC, ATD, and\/or DVCC) fail to disable loads and\/or chargers when required and is also suitable as a remote controllable main system switch.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePre-charge Circuit\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIn addition to the contactor, a built-in pre-charge circuit prevents high inrush currents when connecting a capacitive load such as a MultiPlus\/Quattro or other inverter, eliminating the need for external pre-charging.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMonitoring and Control\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eMonitor and control the BMS via Bluetooth using the VictronConnect App or a GX device such as a Cerbo GX and the VRM Portal. A built-in battery monitor that operates similarly as the other Victron Energy battery monitors, provides data such as state of charge, voltage, current, historical data, status info, and more in real-time and with instant readout even without the need to connect to the BMS, allowing diagnostic at a glance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDVCC closed Loop Control as Well as ATC\/ATD Contacts\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCompatible Victron inverters\/chargers and solar chargers are automatically controlled via a connected GX device and DVCC. The ATC\/ATD contacts can be used to control other chargers and loads that have a remote on\/off port.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eProgrammable Relay\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe relay can be used either as an alarm relay (combined with the pre-alarm) or to control an alternator via its external regulator (ignition cable). In Alternator ATC mode, the relay will only activate when the contactor is closed. Alternator ATC contact of the alternator opens first and then with a delay of 2 seconds the contactor. These 2 seconds ensure that the alternator is switched off before the battery is disconnected from the system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAUX Terminal\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe advantage of the onboard auxiliary power supply (1.1 A @ system voltage) is to provide power to specific loads (i.e. a GX device) after the BMS has shut down the loads in the event of a low cell voltage event. If no charge voltage is detected within 5 minutes, the BMS, including the AUX connection switches off.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eVE.Can and NMEA 2000 Data Communication\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eVE.Can allows for easy connection (standard RJ45 network cable) and communication with a GX device. Since the CANbus protocol is based on NMEA 2000 (and J1939), it is easy to integrate into a marine network and feed a marine MFD with data (requires a VE.Can to NMEA 2000 micro-C male cable).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eLynx Distributor Fuse Monitoring\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eRead out the fuse status and receive an alarm in case a fuse is blown. The Lynx Smart BMS monitors up to 4 connected Lynx Distributors and their fuses via VictronConnect or a GX device 1) To reduce the required balancing time, we recommend using as many different batteries in series as possible for the application. 24 V systems are best built using 24 V batteries, and a 48 V system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThis System Contains the Following Components:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eLynx Distributor with 2 fused paralleled lithium-ion smart batteries.\u003c\/li\u003e\n\u003cli\u003eLynx Smart BMS with BMS, contactor, and battery monitor\u003c\/li\u003e\n\u003cli\u003eA second Lynx distributor provides fused connections for inverter\/charger(s), loads and chargers (additional modules can be added if more connections are needed)\u003c\/li\u003e\n\u003cli\u003eA Cerbo GX (or other GX device) to read out the Lynx Smart BMS and Lynx Distributor data.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBattery Voltage Range: 9 – 60 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum Input Voltage: 75 VDC\u003c\/li\u003e\n\u003cli\u003eSupported System Voltages: 12, 24, or 48 V\u003c\/li\u003e\n\u003cli\u003eReverse Polarity Protection: No\u003c\/li\u003e\n\u003cli\u003eMain Safety Contactor Continuous Current Rating: 1000 A continuous\u003c\/li\u003e\n\u003cli\u003eMain Safety Contactor Peak Current Rating: 1200 A for 5 minutes \u003c\/li\u003e\n\u003cli\u003ePower Consumption OFF Mode: 0.3 mA for all system voltages\u003c\/li\u003e\n\u003cli\u003ePower Consumption in Standby Mode: Approximately 0.6 W (50 mA at 12 V)\u003c\/li\u003e\n\u003cli\u003ePower Consumption in ON Mode: Approx. 2.6 W (217 mA at 12 V) depending on the state of the relays\u003c\/li\u003e\n\u003cli\u003eApproximately 4.2 W (350 mA at 12 V) depending on the state of the relays\u003c\/li\u003e\n\u003cli\u003eMinimum Load Resistance for Pre-Charging: 10 Ω and above for 12 V systems, 20 Ω and above for 24 V and 48 V systems\u003c\/li\u003e\n\u003cli\u003eAUX Output Maximum Current Rating: 1.1 A continuous, protected by resettable fuse\u003c\/li\u003e\n\u003cli\u003eAllow-to-Charge Port Maximum Current Rating: 0.5 A at 60 VDC, protected by a resettable fuse\u003c\/li\u003e\n\u003cli\u003eAllow-to-Discharge Port Maximum Current Rating: 0.5 A at 60VDC, protected by a resettable fuse\u003c\/li\u003e\n\u003cli\u003eAlarm Relay (SPDT) Maximum current Rating: 2 A at 60 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBusbar: M10 (Torque: 17 Nm)\u003c\/li\u003e\n\u003cli\u003eVE.Can: RJ45\u003c\/li\u003e\n\u003cli\u003eI\/O: Removable multi-connector with screw terminals\u003c\/li\u003e\n\u003cli\u003eBattery BTV Cables: Male and female circular 3-pole connector with M8 screw ring Up to 20 batteries can be connected in one system Lynx Distributor fuse monitoring (up to 4 modules) RJ10 (cable ships with each Lynx Distributor)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePhysical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEnclosure Material: ABS\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions (h x w x d): 230 x 180 x 100 mm\u003c\/li\u003e\n\u003cli\u003eUnit Weight: 2.7 kg\u003c\/li\u003e\n\u003cli\u003eBusbar Material: Tinned copper\u003c\/li\u003e\n\u003cli\u003eBusbar Dimensions (h x w): 8 x 30 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eEnvironmental Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOperating Temperature Range: -40 °C to +60 °C\u003c\/li\u003e\n\u003cli\u003eStorage Temperature Range: -40 °C to +60 °C\u003c\/li\u003e\n\u003cli\u003eHumidity Max.: 95 % (non-condensing)\u003c\/li\u003e\n\u003cli\u003eProtection Class: IP22\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSafety: EN-IEC 63000:2018\u003c\/li\u003e\n\u003cli\u003eEMC: EN-IEC 61000-6-3:2007\/A1:2011\/AC:2012\u003c\/li\u003e\n\u003cli\u003eQMS: NEN-EN-ISO 9001:2015\u003c\/li\u003e\n\u003c\/ul\u003e\u003cstrong\u003ePlease contact your dealer for any returns, repairs or support issues related to this product.\u003c\/strong\u003e \u003c!--- cis2:m2lmm51t ---\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45811667435572,"sku":"LYN034170210","price":1059.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0551\/8462\/1620\/files\/victron-lynx-smart-bms-1000-battery-management-system-flithium-smart-batteriesbattery-management-systemslyn034170210-3733330.jpg?v=1769782690"},{"product_id":"victron-lynx-smart-bms-500-ng-m10","title":"Victron Lynx Smart BMS 500 NG (M10)","description":"\u003cp\u003e\u003cstrong\u003eLynx Smart BMS 500 NG (M10)\u003c\/strong\u003e\u003c\/p\u003e\u003cp id=\"isPasted\"\u003eThe Lynx Smart BMS NG is a dedicated Battery Management System (BMS) designed specifically for the Victron Lithium NG batteries. These batteries utilize Lithium Iron Phosphate (LiFePO4) technology and are available in 12.8 V, 25.6 V, and 51.2 V variants with various capacities. They can be configured in series, parallel, and series\/parallel arrangements, allowing for the creation of battery banks with system voltages of 12V, 24V, or 48V. The maximum number of batteries in a single system is 50, enabling a maximum energy storage of 192kWh in a 12V system and up to 384kWh in a 24V and 48V system. For comprehensive details about these batteries, visit the Victron Lithium NG battery product page. \u003c\/p\u003e\u003cp\u003eOut of the various BMSes available* for the Lithium NG batteries, the Lynx Smart BMS NG is the most feature-rich and complete option and integrates seamlessly with other M10 products in the Lynx Distributor system. It is available in 500 A (M10) and 1000 A (M10) versions\u003csup\u003e1\u003c\/sup\u003e).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBuilt-in 500 A or 1000 A Contactor \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAvailable in 500 A (M10) and 1000 A (M10) versions\u003c\/li\u003e\n\u003cli\u003eActs as a secondary safety system to protect the battery in case primary controls (ATC, ATD, and\/or DVCC) fail\u003c\/li\u003e\n\u003cli\u003eSuitable as a remote controllable main system switch\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePre-Charge Circuit \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePrevents high inrush currents when connecting capacitive loads like inverters\u003c\/li\u003e\n\u003cli\u003eEliminates the need for external pre-charging devices\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMonitoring \u0026amp; Control \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBluetooth connectivity for monitoring and control via the VictronConnect App or VE.Can connectivity in combination with GX devices such as the Cerbo GX or Ekrano GX and the VRM portal\u003c\/li\u003e\n\u003cli\u003eReadout of cell voltages and temperatures also on GX devices and the VRM portal\u003c\/li\u003e\n\u003cli\u003eBuilt-in battery monitor provides data such as state of charge, voltage, current, historical data, status info, and more in real-time\u003c\/li\u003e\n\u003cli\u003eDiagnostic at a Glance with Instant Readout\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDVCC Closed Loop Control as well as ATC\/ATD Contacts \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCompatible Victron inverter\/chargers, the Orion XS 12\/12-50A DC-DC battery charger, and solar charge controllers are automatically controlled via a connected GX device and DVCC.\u003c\/li\u003e\n\u003cli\u003eATC\/ATD contacts can be used to control other chargers and loads that have a remote on\/off port\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eProgrammable Relay \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCan be used either as an alarm relay (combined with the pre-alarm) or to control an alternator via its external regulator (ignition cable)\u003c\/li\u003e\n\u003cli\u003eFeatures Alternator ATC mode for safe alternator disconnection before battery disconnects\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eAUX Terminal \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOnboard auxiliary power supply (1.1 A @ system voltage) for powering specific loads (i.e. a GX device) post-BMS shutdown\u003c\/li\u003e\n\u003cli\u003eAutomatic shutdown of BMS and AUX connection if no charge voltage is detected within 5 minutes after a low voltage event\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVE.Can and NMEA 2000 Data Communication \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEasy connection and communication with GX devices via VE.Can using a standard RJ45 network cable\u003c\/li\u003e\n\u003cli\u003eIntegration into marine networks via NMEA 2000 protocol (requires a VE.Can to NMEA 2000 micro-C male cable)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLynx Distributor Fuse Monitoring \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMonitor fuse status of up to 4 connected Lynx Distributors via VictronConnect or GX devices\u003c\/li\u003e\n\u003cli\u003eReceive alarms in case of blown fuses\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e) Up to 5 BMS-es can be paralleled. This requires a firmware update, expected in Q3 2024.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBattery Voltage Range: 9 – 60 VDC \u003c\/li\u003e\n\u003cli\u003eMaximum Input Voltage: 75 VDC \u003c\/li\u003e\n\u003cli\u003eSupported System Voltages: 12, 24, or 48V \u003c\/li\u003e\n\u003cli\u003eReverse Polarity Protection: No \u003c\/li\u003e\n\u003cli\u003eMain Safety Contactor Continuous Current Rating: 500 A continuous \u003c\/li\u003e\n\u003cli\u003eMain Safety Contactor Peak Current Rating: 600 A for 5 minutes \u003c\/li\u003e\n\u003cli\u003ePower Consumption OFF Mode: 0.3 mA for all system voltages \u003c\/li\u003e\n\u003cli\u003ePower Consumption in Standby Mode: Approximately 0.6 W (50 mA at 12 V) \u003c\/li\u003e\n\u003cli\u003ePower Consumption in ON Mode: Approx. 2.6 W (217 mA at 12 V) depending on the state of the relays \u003c\/li\u003e\n\u003cli\u003eMinimum Load Resistance for Pre-Charging: 10 Ω and above for 12 V systems 20 Ω and above for 24 V and 48 V systems \u003c\/li\u003e\n\u003cli\u003eAUX Output Maximum Current Rating: 1.1 A continuous, protected by resettable fuse \u003c\/li\u003e\n\u003cli\u003eAllow-to-Charge Port Maximum Current Rating: 0.5 A at 60 VDC, protected by resettable fuse \u003c\/li\u003e\n\u003cli\u003eAllow-to-Discharge Port Maximum Current Rating: 0.5 A at 60VDC, protected by resettable fuse\u003c\/li\u003e\n\u003cli\u003eAlarm Relay (SPDT) Maximum Current Rating: 2 A at 60 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBusbar: M10 (Torque: 33 Nm) – can be combined with all M10 Lynx products \u003c\/li\u003e\n\u003cli\u003eVE.Can: RJ45 \u003c\/li\u003e\n\u003cli\u003eI\/O: Removable multi-connector with screw terminals \u003c\/li\u003e\n\u003cli\u003eBattery BTV Cables: Male and female circular 3-pole connector with M8 screw ring Up to 50 batteries can be connected in one system \u003c\/li\u003e\n\u003cli\u003eLynx Distributor Fuse Monitoring (up to 4 modules): RJ10 (cable ships with each Lynx Distributor)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePhysical:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEnclosure Material: ABS \u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions (H x W x D): 190 x 180 x 80 mm \u003c\/li\u003e\n\u003cli\u003eUnit Weight: 1.9 kg \u003c\/li\u003e\n\u003cli\u003eBusbar Material: Tinned copper \u003c\/li\u003e\n\u003cli\u003eBusbar Dimensions (H x W): 8 x 30 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOperating Temperature Range: -40 °C to +60 °C \u003c\/li\u003e\n\u003cli\u003eStorage Temperature Range: -40 °C to +60 °C \u003c\/li\u003e\n\u003cli\u003eHumidity: Max. 95 % (non-condensing) \u003c\/li\u003e\n\u003cli\u003eProtection Class: IP22\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSafety: EN-IEC 63000:2018 \u003c\/li\u003e\n\u003cli\u003eEMC: EN-IEC 61000-6-3:2007\/A1:2011\/AC:2012 \u003c\/li\u003e\n\u003cli\u003eQMS: NEN-EN-ISO 9001:2015\u003c\/li\u003e\n\u003c\/ul\u003e\u003cstrong\u003ePlease contact your dealer for any returns, repairs or support issues related to this product.\u003c\/strong\u003e \u003c!--- cis2:m2lmm51t ---\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45811667533876,"sku":"LYN034160310","price":884.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0551\/8462\/1620\/files\/victron-lynx-smart-bms-500-ng-m10battery-management-systemslyn034160310-4300299.jpg?v=1769782689"},{"product_id":"victron-lynx-smart-bms-1000-ng-m10-mgmt-system","title":"Victron Lynx Smart BMS 1000 NG (M10) MGMT System","description":"\u003cp\u003e\u003cstrong\u003eLynx Smart BMS 1000 NG (M10) MGMT System\u003c\/strong\u003e\u003c\/p\u003e\u003cp id=\"isPasted\"\u003eThe Lynx Smart BMS NG is a dedicated Battery Management System (BMS) designed specifically for the Victron Lithium NG batteries. These batteries utilize Lithium Iron Phosphate (LiFePO4) technology and are available in 12.8 V, 25.6 V, and 51.2 V variants with various capacities. They can be configured in series, parallel, and series\/parallel arrangements, allowing for the creation of battery banks with system voltages of 12V, 24V, or 48V. The maximum number of batteries in a single system is 50, enabling a maximum energy storage of 192kWh in a 12V system and up to 384kWh in a 24V and 48V system. For comprehensive details about these batteries, visit the Victron Lithium NG battery product page. \u003c\/p\u003e\u003cp\u003eOut of the various BMSes available* for the Lithium NG batteries, the Lynx Smart BMS NG is the most feature-rich and complete option and integrates seamlessly with other M10 products in the Lynx Distributor system. It is available in 500 A (M10) and 1000 A (M10) versions\u003csup\u003e1\u003c\/sup\u003e).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBuilt-in 500 A or 1000 A Contactor \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eLynx Smart BMS NG 500A A Lynx Smart BMS NG 1000A \u003c\/li\u003e\n\u003cli\u003eAvailable in 500 A (M10) and 1000 A (M10) versions\u003c\/li\u003e\n\u003cli\u003eActs as a secondary safety system to protect the battery in case primary controls (ATC, ATD, and\/or DVCC) fail\u003c\/li\u003e\n\u003cli\u003eSuitable as a remote controllable main system switch\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePre-charge Circuit \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePrevents high inrush currents when connecting capacitive loads like inverters\u003c\/li\u003e\n\u003cli\u003eEliminates the need for external pre-charging devices\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMonitoring \u0026amp; Control \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBluetooth connectivity for monitoring and control via the VictronConnect App or VE.Can connectivity in combination with GX devices such as the Cerbo GX or Ekrano GX and the VRM portal\u003c\/li\u003e\n\u003cli\u003eReadout of cell voltages and temperatures also on GX devices and the VRM portal\u003c\/li\u003e\n\u003cli\u003eBuilt-in battery monitor provides data such as state of charge, voltage, current, historical data, status info, and more in real-time\u003c\/li\u003e\n\u003cli\u003eDiagnostic at a glance with Instant Readout\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDVCC Closed Loop Control as well as ATC\/ATD Contacts \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCompatible Victron inverter\/chargers, the Orion XS 12\/12-50A DC-DC battery charger, and solar charge controllers are automatically controlled via a connected GX device and DVCC.\u003c\/li\u003e\n\u003cli\u003eATC\/ATD contacts can be used to control other chargers and loads that have a remote on\/off port\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eProgrammable Relay \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCan be used either as an alarm relay (combined with the pre-alarm) or to control an alternator via its external regulator (ignition cable)\u003c\/li\u003e\n\u003cli\u003eFeatures Alternator ATC mode for safe alternator disconnection before battery disconnects\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eAUX Terminal \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOnboard auxiliary power supply (1.1 A @ system voltage) for powering specific loads (i.e. a GX device) post-BMS shutdown\u003c\/li\u003e\n\u003cli\u003eAutomatic shutdown of BMS and AUX connection if no charge voltage is detected within 5 minutes after a low voltage event\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVE.Can and NMEA 2000 Data Communication \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEasy connection and communication with GX devices via VE.Can using a standard RJ45 network cable\u003c\/li\u003e\n\u003cli\u003eIntegration into marine networks via NMEA 2000 protocol (requires a VE.Can to NMEA 2000 micro-C male cable)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLynx Distributor Fuse Monitoring \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMonitor fuse status of up to 4 connected Lynx Distributors via VictronConnect or GX devices\u003c\/li\u003e\n\u003cli\u003eReceive alarms in case of blown fuses\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e) Up to 5 BMS-es can be paralleled. This requires a firmware update, expected in Q3 2024.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBattery Voltage Range: 9 – 60 VDC \u003c\/li\u003e\n\u003cli\u003eMaximum Input Voltage: 75 VDC \u003c\/li\u003e\n\u003cli\u003eSupported System Voltages: 12, 24, or 48 V \u003c\/li\u003e\n\u003cli\u003eReverse Polarity Protection: No \u003c\/li\u003e\n\u003cli\u003eMain Safety Contactor Continuous Current Rating: 1000 A continuous \u003c\/li\u003e\n\u003cli\u003eMain Safety Contactor Peak Current Rating: 1200 A for 5 minutes\u003c\/li\u003e\n\u003cli\u003ePower Consumption OFF Mode: 0.3 mA for all system voltages \u003c\/li\u003e\n\u003cli\u003ePower Consumption in Standby Mode: Approximately 0.6 W (50 mA at 12 V) \u003c\/li\u003e\n\u003cli\u003ePower Consumption in ON Mode: Approximately 4.2 W (350 mA at 12 V) depending on the state of the relays\u003c\/li\u003e\n\u003cli\u003eMinimum Load Resistance for Pre-Charging: 10 Ω and above for 12 V systems 20 Ω and above for 24 V and 48 V systems \u003c\/li\u003e\n\u003cli\u003eAUX Output Maximum Current Rating: 1.1 A continuous, protected by resettable fuse \u003c\/li\u003e\n\u003cli\u003eAllow-to-Charge Port Maximum Current Rating: 0.5 A at 60 VDC, protected by resettable fuse \u003c\/li\u003e\n\u003cli\u003eAllow-to-Discharge Port Maximum Current Rating: 0.5 A at 60VDC, protected by resettable fuse\u003c\/li\u003e\n\u003cli\u003eAlarm Relay (SPDT) Maximum Current Rating: 2 A at 60 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBusbar: M10 (Torque: 33 Nm) – can be combined with all M10 Lynx products \u003c\/li\u003e\n\u003cli\u003eVE.Can: RJ45 \u003c\/li\u003e\n\u003cli\u003eI\/O: Removable multi-connector with screw terminals \u003c\/li\u003e\n\u003cli\u003eBattery BTV Cables: Male and female circular 3-pole connector with M8 screw ring Up to 50 batteries can be connected in one system \u003c\/li\u003e\n\u003cli\u003eLynx Distributor Fuse Monitoring (up to 4 modules): RJ10 (cable ships with each Lynx Distributor)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePhysical:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEnclosure Material: ABS \u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions (H x W x D): 230 x 180 x 100 mm\u003c\/li\u003e\n\u003cli\u003eUnit Weight: 2.7 kg \u003c\/li\u003e\n\u003cli\u003eBusbar Material: Tinned copper \u003c\/li\u003e\n\u003cli\u003eBusbar Dimensions (H x W): 8 x 30 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOperating Temperature Range: -40 °C to +60 °C \u003c\/li\u003e\n\u003cli\u003eStorage Temperature Range: -40 °C to +60 °C \u003c\/li\u003e\n\u003cli\u003eHumidity: Max. 95 % (non-condensing) \u003c\/li\u003e\n\u003cli\u003eProtection Class: IP22\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSafety: EN-IEC 63000:2018 \u003c\/li\u003e\n\u003cli\u003eEMC: EN-IEC 61000-6-3:2007\/A1:2011\/AC:2012 \u003c\/li\u003e\n\u003cli\u003eQMS: NEN-EN-ISO 9001:2015\u003c\/li\u003e\n\u003c\/ul\u003e\u003cstrong\u003ePlease contact your dealer for any returns, repairs or support issues related to this product.\u003c\/strong\u003e \u003c!--- cis2:m2lmm51t ---\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45811667566644,"sku":"LYN034170310","price":1178.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0551\/8462\/1620\/files\/victron-lynx-smart-bms-1000-ng-m10-mgmt-systembattery-management-systemslyn034170310-4780653.jpg?v=1769782689"},{"product_id":"victron-lynx-smart-bms-500-battery-mgmt-system-f-lithium-smart-batteries","title":"Victron Lynx Smart BMS 500 Battery MGMT System f\/Lithium Smart Batteries","description":"\u003cp\u003e\u003cstrong\u003eLynx Smart BMS 500 Battery MGMT System for Lithium Smart Batteries\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe Lynx Smart BMS is a dedicated Battery Management System for Victron Lithium Smart Batteries. There are multiple BMS-es available for our Smart Lithium series of batteries, and the Lynx Smart is the most feature-rich and complete option.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBuilt-in 500A contactor, used as a fall-back safety mechanism and also available as a remote controllable main systems switch\u003c\/li\u003e\n\u003cli\u003eBattery monitor, indicating the state of charge percentage and more data.\u003c\/li\u003e\n\u003cli\u003ePre-alarm signal: provide a warning before the system shuts down due to -for example- a low cell.\u003c\/li\u003e\n\u003cli\u003eBluetooth for use with our VictronConnect App, for setup and monitoring.\u003c\/li\u003e\n\u003cli\u003eLocal and remote monitoring using a Victron GX device, for example, the Cerbo GX.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe Lynx Smart BMS is part of the modular Lynx distribution system.\u003c\/p\u003e\u003cstrong\u003ePlease contact your dealer for any returns, repairs or support issues related to this product.\u003c\/strong\u003e \u003c!--- cis2:m2lmm51t ---\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45811741753396,"sku":"LYN034160200","price":764.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0551\/8462\/1620\/files\/victron-lynx-smart-bms-500-battery-mgmt-system-flithium-smart-batteriesbattery-management-systemslyn034160200-3260213.jpg?v=1769782628"},{"product_id":"victron-smart-bms-cl-12-100-f-victron-lifepo4-batteries-12vdc-only","title":"Victron Smart BMS CL 12\/100 f\/Victron LIFEPO4 Batteries 12VDC Only","description":"\u003cp\u003e\u003cstrong\u003eSmart BMS CL 12\/100 f\/Victron LIFEPO4 Batteries 12VDC Only\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Smart BMS CL 12\/100 is a Battery Management system for Victron lithium-iron-phosphate (LiFePO4) Smart Batteries. It has been specifically designed for 12V systems with a 12V alternator.\u003c\/p\u003e\n\u003cp\u003eThe BMS CL 12\/100 monitors and protects each individual battery cell within the battery (or battery bank) and will disconnect the alternator, charge sources, or DC loads in case of low battery voltage, high battery voltage, or over temperature.\u003c\/p\u003e\n\u003cp\u003eThe dedicated alternator input provides current limiting and one-way traffic from the alternator into the battery, so any size alternator (and start battery) can be safely connected to the Smart Lithium battery or batteries.\u003c\/p\u003e\n\u003cp\u003eThe BMS is also equipped with a remote on\/off the connector, to turn the BMS (and the system) off via a remote switch, and a pre-alarm contact, to give a warning signal before the BMS will disconnect the batteries from the system.\u003c\/p\u003e\n\u003c!--- cis2:m2lmm51t ---\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":46800883253300,"sku":"BMS110022000","price":126.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0551\/8462\/1620\/files\/victron-smart-bms-cl-12100-fvictron-lifepo4-batteries-12vdc-onlybattery-management-systemsbms110022000-1829085.jpg?v=1769781494"},{"product_id":"victron-smart-bms-12-200-f-victron-lifepo4-batteries-12vdc-only","title":"Victron Smart BMS 12\/200 f\/Victron LIFEPO4 Batteries 12VDC Only","description":"\u003cp\u003e\u003cstrong\u003eSmart BMS 12\/200 for Victron LIFEPO4 Batteries 12VDC Only\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Smart BMS 12\/200 is an all-in-one Battery Management system for Victron Lithium-Iron-Phosphate (LiFePO4) Smart Batteries. It has been specifically designed for 12V systems with a 12V alternator such as in vehicles and boats.\u003cbr\u003e\u003cbr\u003eIt combines a Current Limiter, Battery Combiner, and Battery Protector in a robust and compact solution and lets you safely connect any size 12V alternator (and starter battery), loads, and chargers to Smart Lithium batteries.\u003cbr\u003e\u003cbr\u003eThe Smart BMS 12\/200 monitors and protects each individual battery cell within the battery (or battery bank) and will disconnect the alternator, charge sources, or DC loads in case of low battery cell voltage, high battery cell voltage, or over temperature.\u003cbr\u003e\u003cbr\u003eThe dedicated alternator connection provides current limiting and one-way traffic from the alternator into the battery, so any size alternator (and starter battery) can be safely connected to the Smart Lithium battery (or battery bank) and the starter battery is protected from excessive discharge.\u003cbr\u003e\u003cbr\u003eThe BMS is equipped with Bluetooth for monitoring and configuration, a remote on\/off the connector, to turn the BMS (and the system) off via a remote switch, and a pre-alarm contact, to give a warning signal before the BMS will disconnect the batteries from the system.\u003c\/p\u003e\n\u003c!--- cis2:m2lmm51t ---\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":46800883286068,"sku":"BMS210055000","price":209.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0551\/8462\/1620\/files\/victron-smart-bms-12200-fvictron-lifepo4-batteries-12vdc-onlybattery-management-systemsbms210055000-4835085.jpg?v=1769781494"}],"url":"https:\/\/felixzonedi.shop\/collections\/battery-management-systems-bms.oembed","provider":"Off Grid Stores","version":"1.0","type":"link"}